iSCSI Technology Brief

On February 11th 2003, the Internet Engineering Task Force (IETF) ratified the iSCSI standard. The IETF was made up of the industries leading IT technology companies including IBM and Cisco.

The iSCSI specification defined a protocol that allows SCSI commands to be encapsulated in TCP/IP to give computers access to storage devices over common IP networks. Low cost IP Networks are then used as the backbone to connect centralised or distributed storage resources to servers anywhere that an IP connection is available.

Having established the standard, operating system vendors were encouraged to develop iSCSI initiator software (for the computer server) and storage vendors produced iSCSI target storage systems. Any computer with an iSCSI initiator could gain access to the resources of any iSCSI target device through a low cost Gbit Ethernet connection with all the storage provisioning and security features supported by the server operating system.

Free Software
Microsoft had always been an active supporter of iSCSI and it demonstrated this on June 30th 2003 when it announced the free availability of iSCSI initiator code for Windows 2000, Windows 2003 and XP Pro. By downloading and installing this software from the Microsoft web site all applicable Windows servers, desktops and laptops became capable of receiving storage network services through their existing NIC interfaces. Without any hardware changes or additional cost millions of computers running Windows have become SAN ready clients.

Free iSCSI initiator software for servers using other operating systems (including many Linux and UNIX flavours) are widely available and the principles involved are the same. Mixed host operating systems are also entirely compatible with iSCSI storage systems.

Architecture
The beauty of an iSCSI based storage system is its simplicity. Any target storage capacity provisioned to a server (initiator) simply appears to that server as if it had a new disk directly inside that server, even though it may be hundreds of metres away or even over a wide area network at another location if bandwidth permits.

Anything that can be done with an internal disk can also be done with a remote storage pool provisioned using iSCSI over an IP connection.

So the disk can be backed up, mirrored, a point in time copy of the changes (snapshot) taken or the disk replicated without using expensive proprietary solutions.

A single iSCSI target storage system may provide storage capacity to one server, to a few servers, or to many servers. Each server would be allocated a part of the iSCSIs target storage capacity, and that part would be secure and owned only by the initiating server.

Westek offers iSCSI target storage systems to allow this scaleable, flexible and cost effective storage architecture to be deployed on a small, medium or large scale.

Connection and setup is very simple, and the provisioned storage capacity may be expanded as required. Multiple Gbit connections may also be made to the servers and to the iSCSI target storage device if required. Performance is greatly enhanced by connecting servers through a non-blocking Gbit switch rather than connecting directly to the iSCSI unit.

Performance
In terms of performance, a single Gbit Ethernet connection is capable of providing a data rate of a little over 120MBytes per second which is excellent performance compared with many direct attached storage devices.

SANs may be built using Gbit Ethernet switches to allow connection to multiple servers and multiple iSCSI storage systems. The switch needs to support Jumbo Frames to provide the best level of performance.

The Gbit Ethernet port connections on the host computers ideally also need to be high performance. If you are adding a Gbit Ethernet card to your host computer system, then it should be a 64bit PCI-X card (or PC Express) and use a fast slot (133MHz) if possible for best performance.

iSCSI Target Architecture In A Windows Environment
There is a key difference between an iSCSI Target and any other SAN software, in that implementing an iSCSI Target extends the existing Windows storage features instead of offering alternatives to them. By adopting this unique approach it effectively extends Windows to be a SAN aware operating system.

Each server that requires storage to be provisioned to it requires simple and free iSCSI initiator software to be added which may be installed without even rebooting the computer. Each iSCSI based storage unit (The iSCSI target) is then used to provide storage capacity to that server via simple low cost Gbit Ethernet. Each iSCSI target storage system may be provisioned to provide storage capacity to a large number of server initiators. Similarly many iSCSI target storage systems may be used to provide scalable storage capacity. The architecture is flexible and may be one to many, many to one, or many to many with no additional licensing costs

The iSCSI target storage system connects seamlessly with the freely available iSCSI Microsoft initiator code to form the foundation building block of the Windows SAN and extending its capabilities further.

Examples of the solutions enabled are:

Extending disk management to provision disks network wide
Extend VSS (Volume Shadow copy Service - Microsofts snapshot feature in W2003) to take point in time copies anywhere and at any time
Extend disk mounting capability to allow remote file systems to be viewed locally
Leverage of Windows security (Microsoft standards CHAP & IPsec) to protect the SAN.

Data Security
There are a number of ways to provide added data security and data recovery using iSCSI based storage.

1. Disk Mirroring
One simple way is to allocate storage capacity on two separate iSCSI target storage systems, and simply mirror the data using the features supported under Windows and most other operating systems. Data is then duplicated in real time onto both storage devices, and is still available to the server should the data on either one of the storage systems become unavailable.

2. Snapshot and backup/restore
Snapshot is a feature to enable a point in time copy of iSCSI target data to be created. The snapshot copy will contain only changes made to the data since the previous snapshot was created. Using this snapshot data can be reviewed and restored back to an earlier version to overcome data deletion, data corruption and virus infected files. The snapshot can be rolled back to the original state entirely or individual files restored to a pervious version. The snapshot can also be used to backup the iSCSI target even if the data is live. As the snapshot is a copy of the changes made to the live data it can be presented to any iSCSI initiator and used to backup the volume in full.

If the Initiator server is using Windows 2003 then Microsofts in built volume shadow copy feature can be used for performing snapshots of file based data. True data volume snapshot at the block level is available as an optional feature on the iSCSI target storage system itself and does not involve the host server system.

Snapshots may be scheduled to happen automatically at preset intervals if required.

3. Data replication with seamless failover
Synchronous data replication is another option that allocates one iSCSI target as the primary data storage device, and synchronously writes data to a second iSCSI target device using a dedicated and separate Gbit connection. Should the primary unit fail for any reason, the secondary unit tales over in a seamless fashion using its inbuilt failover capabilities. This does not involve the host computer at all, unlike disk mirroring, and is entirely automatic. Furthermore the host is only writing one set of data to the primary storage device (unlike host based mirroring) and the replication is taken care of by the iSCSI targets themselves.

4. Clustering
The iSCSI Target is cluster aware such that a single iSCSI Target storage system may be connected separately to two servers setup in a cluster. Access to data is available should either server fail. Clustering is provided by the host operating system (such as Microsofts Advanced server edition of Windows 2003)

Is iSCSI the right solution for my data storage needs?
iSCSI is a block based storage technology, just like direct attached storage (DAS) or a fibre channel SAN system. It is therefore entirely compatible with database applications including SQL and Microsoft Exchange, unlike Network Attached Storage (NAS) file based storage systems.

NAS systems offer IP connections to a central file based storage system. NAS systems are operating system and file system dependant. They are great for offering a file based shared storage system, but performance is usually lower than a DAS system and they are useful really only for file based applications and not for use with applications such as an SQL database or Microsoft Exchange data.

Today DAS systems are available with either SCSI or Fibre channel host connections. The latest U320 SCSI provides data rates in theory up to 320MBytes per second. The disadvantages are that a relatively expensive U320 SCSI interface is required in each host computer and the storage system must be within a few meters of the server clearly not good for building a SAN or where the server systems are in an office environment.

Fibre channel provides up to 200MBytes per second and allows the storage system to be remotely located and a SAN to be built. However fibre channel infrastructure, interfaces and switches are expensive and require specialist management suites further increasing the cost of ownership.

The iSCSI initiator driver does add a small load to the host cpu, since if using a standard TCI/IP Ethernet card, then the host CPU performs the iSCSI encapsulation part of the protocol process. In most systems this is not an issue, and, if it is, then TOE cards which off load the encapsulation are available to replace the standard Gbit Ethernet interface.

Current Ethernet interfaces are 1Gbit per second, and around 120MBytes per second is achievable over a single Gbit link. 10Gbit Ethernet is now available from a few vendors including Intel. At the moment 10Gbit Ethernet is more expensive than fibre channel and so the cost advantages of iSCSI are lost. As with all new technologies, this is likely to fall dramatically in cost over the next few years and provide iSCSI with a strong future leading to very high performance possibilities to challenge even the fastest fibre channel products available today.

iSCSI provides a cost effective way to provide scaleable storage for many applications. Its performance is high enough to support real time data, even for high definition TV or multiple real time video streams.

An iSCSI based storage SAN is easy to manage, standards based, and provides a scaleable solution as your storage requirements grow.

Westek Technology are exhibiting at Storage Expo the UK's largest and most important event dedicated to data storage, now in its 5th year, the show features a comprehensive FREE education programme, and over 90 exhibitors at the National Hall, Olympia, London from 12 - 13 October 2005 www.storage-expo.com

Add a Comment

No messages on this article yet

Editorial: +44 (0)1892 536363
Publisher: +44 (0)208 440 0372
Subscribe FREE to the weekly E-newsletter